Cryo-confocal fluorescence microscope
The submission deadline has passed. The notice is closed.
simap.ch
Overview
The system must work with standard cryo-EM grids and AutoGrids, integrate stage control in its software and form a ready-to-use hardware/software package. Image quality, sample recovery without quality loss and usability are highlighted. The notice does not state a price or award criteria.
Information based on the public notice
Ask about this tender
What the buyer needs
- Subcontractors are permitted; consortia are not.
Tender details
- Buyer
- Institute of Biochemistry and Molecular Medicine
- Country
Switzerland
- Procedure
- open
- Classification
- Scientific microscopes · CPV 38510000
- Notice reference
- 43946 · 43946-01
- Offer validity
- Offers are valid until 31 January 2027.
What to check in the tender documents
- No contract value or award criteria is stated in the public notice.
Original notice
Read the original description
Procurement of a cryo-confocal fluorescence microscope
Official source: simap.ch ↗
Notice updates
November 6, 2026 · Version 2
Summary and analysis updated · Tender facts updated · Source notice details updated · Source references updated · Status changed · Notice update added
Procurement of a cryo-confocal fluorescence microscope
Procurement of a cryo-confocal fluorescence microscope The IBMM wishes to procure a brand-new cryo-kFM, which is to be integrated into a cryo-CLEM workflow for cellular cryo-ET and in situ structural biology. The cryo-kFM is to be equipped with at least four fluorescence channels (lasers) and feature a highly sensitive, high-resolution detector system for confocal microscopy. The microscope system should also allow switching between confocal and wide-field fluorescence microscopy by being fitted with the appropriate light sources, filters and camera. Furthermore, it should be equipped with at least one cryo-compatible air objective with the highest possible numerical aperture and a magnification of at least 50x. Furthermore, the cryo-kFM should feature a cryo-stage that allows samples (cryo-EM grids with vitrified cells) to be loaded, imaged and unloaded at temperatures below –150°C, without the samples ever being exposed to higher temperatures and without them being significantly contaminated by condensing moisture. The cryo-stage must be compatible with standard cryo-EM grids and so-called AutoGrids for the subsequent cryo-CLEM steps. The motorised cryo-stage should be integrated into the user interface of the software used to operate the cryo-kFM. This user interface should be as simple and efficient to use as possible; the entire microscope system should comprise a complete, ready-to-use hardware and software package. Of particular importance are high imaging quality, robustness when retrieving the imaged samples without any loss of quality for the subsequent cryo-CLEM steps (cryo-FIB milling and cryo-ET), and user-friendliness.
October 11, 2026 · Version 1
Published
Procurement of a cryo-confocal fluorescence microscope
Procurement of a cryo-confocal fluorescence microscope The IBMM wishes to procure a brand-new cryo-kFM, which is to be integrated into a cryo-CLEM workflow for cellular cryo-ET and in situ structural biology. The cryo-kFM is to be equipped with at least four fluorescence channels (lasers) and feature a highly sensitive, high-resolution detector system for confocal microscopy. The microscope system should also allow switching between confocal and wide-field fluorescence microscopy by being fitted with the appropriate light sources, filters and camera. Furthermore, it should be equipped with at least one cryo-compatible air objective with the highest possible numerical aperture and a magnification of at least 50x. Furthermore, the cryo-kFM should feature a cryo-stage that allows samples (cryo-EM grids with vitrified cells) to be loaded, imaged and unloaded at temperatures below –150°C, without the samples ever being exposed to higher temperatures and without them being significantly contaminated by condensing moisture. The cryo-stage must be compatible with standard cryo-EM grids and so-called AutoGrids for the subsequent cryo-CLEM steps. The motorised cryo-stage should be integrated into the user interface of the software used to operate the cryo-kFM. This user interface should be as simple and efficient to use as possible; the entire microscope system should comprise a complete, ready-to-use hardware and software package. Of particular importance are high imaging quality, robustness when retrieving the imaged samples without any loss of quality for the subsequent cryo-CLEM steps (cryo-FIB milling and cryo-ET), and user-friendliness.
https://www.simap.ch/de/project-detail/95e086df-fdc5-46d3-b9d2-5e3bb75cf5d8
Source retrieved: 2026-11-06T10:18:22.100237Z