Reconditioning, calibration and testing of one Schneider Electric 2000A air circuit breaker for Load B
Outcome
Submissions closed on 13 October 2026. No award has been published yet. Open tenders like this one are listed below.
- Place
- Bukidnon, Philippines
- Closing timestamp is present in the canonical snapshot; timezone and a public printable closing time are not stated in the retrieved abstract.
- Time not stated
- Contract value
- ₱100,000
- Approved contract budget
- Lots
- 1 lot
- Classification
- Procurement
- Published
- October 8, 2026
- PhilGEPS
Overview
Bukidnon State University seeks reconditioning, calibration and testing of one Schneider Electric 2000A ACB for Load B. Negotiated procurement - small value procurement (Section 34); goods; approved budget PHP 100,000; delivery period 30 days. The official printable notice identifies solicitation 26-09-1351 and the exact reference. The legacy detail page says the opportunity is closed and requires login for former-opportunity details, so no award or further terms are asserted from that page. The full public printable abstract is retained as the primary notice.
Information based on the public notice
Ask about this tender
What the buyer needs
- Bukidnon State University seeks reconditioning, calibration and testing of one Schneider Electric 2000A ACB for Load B. Negotiated procurement - small value procurement (Section 34); goods; approved budget PHP 100,000; delivery period 30 days. The official printable notice identifies solicitation 26-09-1351 and the exact reference. The legacy detail page says the opportunity is closed and requires login for former-opportunity details, so no award or further terms are asserted from that page. The full public printable abstract is retained as the primary notice.
Lots
1 unit for Load B
Tender details
- Buyer
- BUKIDNON STATE UNIVERSITY
- Country
Philippines
- Procedure
- Not stated in the notice
- Classification
- Procurement
- Notice reference
- 13279088
- Estimated value / approved budget
- 100000 PHP
- Deadline
- Closing timestamp is present in the available notice information; timezone and a public printable closing time are not stated in the retrieved abstract.
What to check in the tender documents
- The old detail view requires login for this closed opportunity; no award is asserted.
Original notice
Read the original description
Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B)
Official source: PhilGEPS ↗
Notice updates
October 15, 2026 · Version 2
Buyer updated · Classification updated · Deadline information updated · Summary and analysis updated · Tender facts updated · Original notice updated · Deadline updated · Source notice details updated · Source references updated · Status changed
Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B)
Help printableBidNoticeAbstract Bid Notice Abstract Request for Quotation (RFQ) Reference Number 13279088 Procuring Entity BUKIDNON STATE UNIVERSITY Title Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B) Area of Delivery Bukidnon Solicitation Number: 26-09-1351 Trade Agreement: Implementing Rules and Regulations Procurement Mode: Negotiated Procurement - Small Value Procurement (Sec. 34) Classification: Goods Category: General Repair and Maintenance Services Approved Budget for the Contract: PHP 100,000.00 Delivery Period: 30 Day/s Client Agency: Contact Person: Beulah Leah Libertad Pailagao Administrative Officer I Fortich St. Malaybalay City Malaybalay City Bukidnon Philippines 8700 63-88-8135661 rfq@buksu.edu.ph Status Closed Associated Components 1 Bid Supplements 0 Document Request List 1 Date Published 09/10/2026 Last Updated / Time 09/10/2026 00:00 AM Closing Date / Time 13/10/2026 14:00 PM Description Item QTY. UOM PARTICULARS / DESCRIPTION AND SPECIFICATIONS APPROVED BRAND UNIT PRICE NO. UNIT COST 1 1 lot Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B) 100,000.00 Conduct an inspection of the internal mechanism to verify that it is free from water intrusion. Check the closing and tripping mechanism.D24 "Test the Trip unit or equivalent but not limited to: • Long-time delay • Short-time delay • Instantaneous trip • Ground fault protection (if applicable) • High and Low Voltage Protection" Check insulation resistance. (Check per Schneider’s guidelines) Provide the calibration and testing reports, duly signed and sealed by a Professional Electrical Engineer (PEE). Created by Beulah Leah Libertad Pailagao Date Created 08/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. © 2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap
October 12, 2026 · Version 1
Published
Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B)
Bid Notice Abstract Request for Quotation (RFQ) Reference Number 13279088 Procuring Entity BUKIDNON STATE UNIVERSITY Title Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B) Area of Delivery Bukidnon Printable Version Solicitation Number: 26-09-1351 Trade Agreement: Implementing Rules and Regulations Procurement Mode: Negotiated Procurement - Small Value Procurement (Sec. 34) Classification: Goods Category: General Repair and Maintenance Services Approved Budget for the Contract: PHP 100,000.00 Delivery Period: 30 Day/s Client Agency: Contact Person: Beulah Leah Libertad Pailagao Administrative Officer I Fortich St. Malaybalay City Malaybalay City Bukidnon Philippines 8700 63-88-8135661 rfq@buksu.edu.ph Status Active Associated Components Order Bid Supplements 0 Document Request List 1 Date Published 09/10/2026 Last Updated / Time 09/10/2026 12:00 AM Closing Date / Time 13/10/2026 2:00 PM Description Item QTY. UOM PARTICULARS / DESCRIPTION AND SPECIFICATIONS APPROVED BRAND UNIT PRICE NO. UNIT COST 1 1 lot Reconditioning, calibration, and testing of Schneider Electric 2000A Air Circuit Breaker (ACB) (1 UNIT FOR LOAD B) 100,000.00 Conduct an inspection of the internal mechanism to verify that it is free from water intrusion. Check the closing and tripping mechanism.D24 "Test the Trip unit or equivalent but not limited to: • Long-time delay • Short-time delay • Instantaneous trip • Ground fault protection (if applicable) • High and Low Voltage Protection" Check insulation resistance. (Check per Schneider’s guidelines) Provide the calibration and testing reports, duly signed and sealed by a Professional Electrical Engineer (PEE).
https://notices.philgeps.gov.ph/GEPSNONPILOT/Tender/SplashBidNoticeAbstractUI.aspx?menuIndex=3&refID=13279088&DirectFrom=OpenOpp&Type=category&BusCatID=46
Source retrieved: 2026-10-15T22:33:57.379564Z