Current repair of a Toshiba Aquilion Prime SP 160 CT scanner

Outcome

Submissions closed on 28 October 2026. No award has been published yet. Open tenders like this one are listed below.

Place
Ukraine
28 October 2026, 00:00 UTC+02
10:00 PM · UTC
Contract value
UAH 216,135
Estimated tender value excluding VAT
Lots
1 lot
Classification
CT scanner repair
Published
October 12, 2026
Prozorro public tender summary and OpenProcurement CDB API

Overview

Zaporizhzhia Regional Clinical Hospital is procuring one repair service for its Toshiba Aquilion Prime SP 160 (TSX-303B) CT scanner, serial number 5CA2242656. The notice identifies replacement of the PX79-81453 ACC2+ board. A specialist must attend the hospital within five working days after a service request, at the contractor’s expense. The estimated value is UAH 216,135 excluding VAT; award is by lowest cost. The submission deadline is 28 October 2026 at 00:00 UTC+02, and service completion is due by 31 December 2026 at 00:00 UTC+02. Work is at the hospital’s CT room in Zaporizhzhia.

Information based on the public notice

What the buyer needs

Repair of one hospital CT scanner, including replacement of the specified ACC2+ board.

Lots

b58e0afa286f4dd495800e6274bf4797 ·Current repair of Toshiba Aquilion Prime SP 160 CT scanner

Tender details

Buyer
КОМУНАЛЬНЕ НЕКОМЕРЦІЙНЕ ПІДПРИЄМСТВО "ЗАПОРІЗЬКА ОБЛАСНА КЛІНІЧНА ЛІКАРНЯ" ЗАПОРІЗЬКОЇ ОБЛАСНОЇ РАДИ
Country
Ukraine
Procedure
aboveThreshold
Classification
CT scanner repair · CPV 50420000-5
Notice reference
UA-2026-10-12-002356-a
Estimated value
UAH 216,135 excluding VAT
Equipment
Toshiba Aquilion Prime SP 160 (TSX-303B), serial 5CA2242656
Repair
Replace PX79-81453 ACC2+ board; one service
Response time
Specialist attends within 5 working days of request, at contractor expense
Award criterion
Lowest cost
Submission deadline
28 October 2026, 00:00 UTC+02
Service deadline
31 December 2026, 00:00 UTC+02

What to check in the tender documents

  • The public record does not identify the full diagnostic and acceptance protocol, warranty terms or service pricing breakdown; linked procurement documents were not opened.
Get started with Ziva

Original notice

Read the original description

Послуги з поточного ремонту комп’ютерного томографу типу Aquilion Prime SP 160 (TSX-303B) (серійний номер 5СА2242656).

Послуги з поточного ремонту комп’ютерного томографу типу Aquilion Prime SP 160 (TSX-303B) (серійний номер 5CA2242656) із заміною запчастини PX79-81453 плата ACC2+. Поточний ремонт проводиться за місцем розташування обладнання за адресою місто Запоріжжя, Оріхівське шосе 10: у відділенні променевої терапії та променевої діагностики – центральний корпус, перший поверх, кабінет КТ. Надання послуг передбачає приїзд спеціалістів на територію Замовника за рахунок Виконавця у строк 5 (п’ять) робочих днів з моменту отримання заявки від Замовника.